FAIL SAFE
HYDRAULIC
MOTOR/BRAKE
UNIT
TYPE - MBW
TYPE MBW
MOTOR SIZE
DISPLACEMENT
MAX. SPEED
MAX. TORQUE
MAX. PRESSURE
DROP
MAX. OIL FLOW
32 50 63 75 100 125 150 200 250 300 400
33.0 49.7 65.9 81.8 101.2 126.1 160.8 200.9 250.8 315.5 399.9
2.02 3.04 4.04 5.01 6.20 7.72 9.85 12.30 15.36 19.32 25.27
rpm cont.
1400 775 750 750 600 475 375 300 240 190 160
rpm int.
lbf.in cont.
Nm int.
lbf.in int.
bar cont.
Nm cont.
psi int.
cm
3
in
3
bar int.
psi int.
lpm cont.
gpm cont.
lpm int.
gpm int.
1600 1000 1000 940 750 600 450 375 300 240 200
44 100 140 195 240 300 360 360 360 360 360
390 885 1240 1730 2120 2660 3190 3190 3190 3190 3190
62 130 170 220 280 340 430 440 450 450 450
550 1150 1505 1950 2480 3010 3810 3890 3982 3 9 8 2 3982
100 140 140 175 175 175 165 130 100 85 70
1450 2030 2030 2540 2540 2540 2390 1890 1450 1230 1020
140 175 175 200 200 200 200 175 140 110 90
2030 2540 2540 2900 2900 2900 2900 2540 2030 1 6 0 0 1310
50 40 50 60 60 60 60 60 60 60 60
11 8.8 11 13.2 13.2 13.2 13.2 13.2 13.2 13.2 13.2
55 50 62 75 75 75 75 75 75 75 75
12.2 11 13.6 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5
L
I
M
I
T
E
D
ADAN LIMITED
RIVERSIDE IND. ESTATE BOSTON LINCOLNSHIRE ENGLAND
Tel: +44 (01205) 311500 Fax: +44 (01205) 358013
The policy of Adan Limited is one of continual development and the right is reserved to alter specifications without notice.
Spring applied pressure release
Static brake torque 3950 lbf.in - 450 Nm
Brake release pressure 380 psi - 26 bar
Maximum brake pressure 300 bar
Maximum drain line pressure 70 psi - 5 bar
Motor drain line must be used if over this rating
Maximum inlet pressure 3250 psi - 224 bar
Maximum pressure drop and speed must not be reached simultaneously.
Intermittent operation may occur for 10% max. of every minute.
At speeds lower than 10 rpm please consult our Technical Department.
Mineral based hydraulic fluids with anti-wear additives are recommended
with a viscosity of 35 mm /s at a temperature of 50 C.
Minimum recommended oil viscosity 13 mm /s at operating temperature.
Recommended oil cleanliness ISO 19/14 with a nominal filtration of
25 micron or better.
Where non-flammable fluids are to be used it is advisable to consult our
Technical Department.
Ambient temperature should be between -30 C and +90 C.
Normal operating temperature should be between +30 C and +60 C.
Maximum operating temperature +85 C.
O
2
2
O
O
O
O
O
SYMBOL c/w MSV
Motor / Brake Precautions
To ensure proper operation of the brake, a separate case
drain back to tank must be used due to the possibility of
return line pressure spikes. A simple schematic of a system
utilizing a motor/ brake is shown in the diagram below.
To achieve proper brake release operation, it is necessary
to bleed out any trapped air and fill brake release cavity and
hoses before all connections are tightened.
It is advisable that the brake release port should be
positioned as near the top of the unit in the installed position.
Caution
All Adan motor / brakes are intended to operate as static
parking brakes, the system should be designed to bring the
load to a stop before the brake is applied.
With large displacement motors it is possible for the motor
to produce higher torques than the brake will hold, it is
critical that the maximum system pressure is limited in these
applications. It is vital that the system relief be set low enough
to ensure the motor is not able to produce more torque than
the brake can hold.
Failure to do so may result in serious injury or death.